At NCQC Laboratory LLP, we provide precise and reliable Electro-Technical Calibration Services to ensure accurate measurement of critical electrical parameters such as voltage, current, resistance, frequency, and power. Our laboratory operates in accordance with ISO/IEC 17025 standards, ensuring full traceability to national and international measurement standards. We serve a wide range of industries including pharmaceuticals, engineering, power generation, and manufacturing, where accuracy is essential for safety and quality. Our experienced technical team uses advanced calibration equipment and follows controlled procedures to deliver highly accurate results. We are committed to minimizing measurement uncertainty and maintaining consistency in instrument performance. Our services support regulatory compliance and help organizations improve operational efficiency. With a strong focus on quality and timely service, NCQC Laboratory LLP is a trusted partner for electro-technical calibration.
What is Electro-Technical Calibration?
Electro-Technical Calibration is the process of verifying and adjusting electrical measuring instruments by comparing them with certified reference standards. It ensures that instruments provide accurate and reliable readings within specified limits. This process helps identify measurement errors and ensures proper functioning of equipment. Regular calibration is essential for maintaining safety, product quality, and compliance with international standards. It also reduces measurement uncertainty and enhances the overall performance of instruments. Electro-technical calibration plays a critical role in ensuring consistency and reliability in industrial and laboratory measurements.
| Parameter | Range | Method for Calibration |
|---|---|---|
| 1 & 3 Phase Power/ Energy Meter | 0.15 W - 9600 W | Direct calibration with multi function calibrator/ Energy meter calibrator |
| AC/DC Ammeter (Analog/ Digital)/ Panel Ampere Meter | 0- 1000 A | Multifunction calibrator with current coil |
| AC/DC Current / | 0- 1000 A | Multifunction calibrator with current coil |
| AC/DC Voltmeter (Analog/ Digital) / Panel Voltmeters | 0- 1000 V | Direct calibration with multi function calibrator |
| Capacitance | 0.50 nf - 110 mF | Direct calibration with multi function calibrator |
| DC Resistance | 1 Ω- 1090 MΩ | Direct calibration with multi function calibrator |
| Decade Capacitance Box | 1 nF – 10mF | Direct Calibration by 6.5 DMM |
| Decade Resistance Box | 1 Ω - 1000 MΩ | Direct Calibration by 6.5 DMM |
| Digital Multimeter/ Clamp meter: AC/DC Voltage | 0- 1000 V | Direct calibration with multi function calibrator |
| Frequency / Frequency Meter | 1 Hz - 2 MHz | Direct calibration with multi function calibrator |
| HV Probe with DMM / kV Meter / HV Tester | 0-27 kV AC/ 0-40 kV DC | Comparasion method by HV probe with DMM |
| Lux Meter | 25-10050 lux | Comparison method by light source and lux meter |
| Multifunction Calibrators | 4 - 20 mA / 1 - 200 mV / | by using multifunction calibrator |
| Oscilloscope (Amplitude, Bandwidth and time Base) | up to 1100 MHz | by using multifunction calibrator |
| pH Meter | 1- 14 pH | "Using Multi–Productcalibrator /Temperature Electrical Calibrator by Simulation Method" |
| Phase Meter | 0- 360° | Direct calibration with multi function calibrator |
| Power Factor Meter | 0-1 pF | Direct calibration with multi function calibrator |
| Power Supply | 0- 1000V/ 10A | Direct Calibration by 6.5 DMM |
| Resistance decade box | 1 Ω to 999 MΩ | Direct Calibration by 6.5 DMM |
| Shunt | 0- 20 A | Direct calibration with multi function calibrator |
| Sound Level Meter | 94 dB, 114 dB | Direct calibration by sound level meter |
| Stop Watch/ Timer / Hour Meter | 0.01 sec.- 24 hr | Comparison by Timer and stop watch calibrator |
| Temperature Simulation (RTD/ Thermocouple) / Temperature controller / Temperature indicator / PID controller | -200°C to 1760°C | Direct calibration with multi function calibrator |
| Universal Calibrators / Loop Calibrator / RTD Calibrator / RTD Simulator | 4 - 20 mA / 1 - 200 mV / Temperature Simulation / Resistance / | Direct calibration with multi function calibrator & 6.5 DMM |
| LCR Meter | 1Ω - 2 kΩ / 10 µH to 1000 mH / 0.5 nF to 330 µF | Direct calibration with multi function calibrator & Inductance Box |
| Conductivity Meter | 1 μs to 1000 ms (1 ohm to 1 Mohm) | Using Multiproduct calibrator by Simulation Method |
| Resistance / Resistance Meter / Megger / Insulation tester / Earth tester / Low Resistance Meter / Micro Ohm meter | 10 µΩ to 1000 GΩ | Using Multi-Product Calibrator / Resistance decade box / High resistance Jig by Direct Method |
| Inductance Meter | 10 µH to 1000 mH | Direct calibration with Inductance Box |
Electro-Technical Calibration is widely used for instruments that measure:
- Voltage (AC/DC)
- Current (AC/DC)
- Resistance
- Frequency
- Power and Energy
- Insulation Resistance
- Capacitance and Inductance