Thermal

+

At NCQC Laboratory LLP, we provide accurate and reliable Thermal Calibration Services to ensure precise measurement of temperature and humidity across critical applications. Our laboratory operates as per ISO/IEC 17025 standards, ensuring full traceability to national and international references. Thermal measurements are essential in industries such as pharmaceuticals, food processing, healthcare, and manufacturing, where product quality and safety depend on controlled temperature conditions. Our experienced team uses advanced calibration equipment like dry block calibrators, liquid baths, and reference sensors to achieve high accuracy. We focus on minimizing measurement uncertainty and maintaining consistency in instrument performance. Our services help organizations meet regulatory requirements and maintain process reliability. With a commitment to quality and timely service, NCQC Laboratory LLP is your trusted partner for thermal calibration needs.

What is Thermal Calibration?

Thermal Calibration is the process of verifying and adjusting temperature and humidity measuring instruments by comparing them with certified reference standards. It ensures that instruments provide accurate and consistent readings within specified limits. This process helps identify deviations and ensures reliable performance of temperature-sensitive equipment. Regular calibration is essential for maintaining product quality, safety, and compliance with regulatory standards. It also helps reduce measurement uncertainty and improves overall process control. Thermal calibration plays a critical role in environments where temperature accuracy is vital.

ParameterRange Method for Calibration
Thermo Hygrometer@50% RH 5 °C to 50 °C Using Temperature & Humidity Indicator with Sensor and Temperature & Humidity Calibrator by Comparison method
Thermo Hygrometer@25°C 20 % RH - 95 % RH Using Temperature & Humidity Indicator with Sensor and Temperature & Humidity Calibrator by Comparison method
Liquid in Glass Thermometer -80 °C - 250 °C Using SSPRT with Precision Temperature Scanner & Liquid Temperature Bath by Comparison method
RTD/Thermocouple, Temperature Sensor with or without Indicators, Temperature Gauge -196 °C to 1200 °C Using SSPRT with Super DAQ Precision Temperature Scanner, Liquid Temperature Bath, 6½ Digit Multimeter and Multifunction calibrator by Comparison method
Humidity Chambers (Single/ multi position) 5 °C - 50 °C Using Temperature & Humidity Indicator with Sensor by Comparison method
Humidity Chambers (Single/ multi position) 15 % RH - 95 % RH Using Temperature & Humidity Indicator with Sensor by Comparison method
Humidity Indicator with Sensor of Chamber (Single Position) 15 % RH - 95 % RH Using Temperature & Humidity Indicator with Sensor by Comparison method
Temperature Indicator with Sensor of Chamber (Single Position) @ 50 %RH 5 °C - 50 °C Using Temperature & Humidity Indicator with Sensor by Comparison method
Deep freezer, Refrigerators, Incubator, -80 °C to 1200 °C Using SSPRT with Super Precision Temperature Scanner by Comparison method
Temperature Bath, Temperature Calibrators, -80 °C to 1200 °C Using SSPRT with Super Precision Temperature Scanner by Comparison method
Chamber, Dry Well Block, Liquid Bath, -80 °C to 1200 °C Using SSPRT with Super Precision Temperature Scanner by Comparison method
Cold Room (Multi position) -80 °C to 1200 °C Using SSPRT with Super Precision Temperature Scanner by Comparison method
Temperature Bath, Temperature Calibrators, Chamber, Dry Well Block, Liquid Bath, Oven Furnace (Multi position) -80 °C - 1200 °C Using RTD Sensors (Minimum 9) / thermocouples with Super Precision Temperature Scanner by Comparison method
Temperature Indicator with sensor of freezer, Incubator (for non medical purpose), Liquid Bath, Dry Well Block, Chambers -80 °C - 200 °C Using SSPRT with Super Precision Temperature Scanner by Comparison method
Temperature Indicator with sensor of Oven, Furnace, Liquid Bath, Dry Well Block, Chambers, Incubator -80 °C - 1200 °C Using SSPRT with Super Precision Temperature Scanner by Comparison method
Thermocouple, Temperature Sensor with or without Indicators, Temperature Gauge -80 °C - 1200 °C Using SSPRT with Precision Temperature Scanner & Liquid Temperature Bath by Comparison method
Temperature indicator / Temperature controller with sensor (full range) -80 to 1200 °C Using SSPRT with Precision Temperature Scanner & Liquid Temperature Bath by Comparison method
Calibration of Temperature gauges (-80 to 1200°C) -80 °C - 1200 °C Using SSPRT with Precision Temperature Scanner & Liquid Temperature Bath by Comparison method
Water bath Amb. to 100°C Using SSPRT with Precision Temperature Scanner by Comparison method
temperature sensors -80 to 1200°C Using SSPRT / S type thermocouple with Super Precision Temperature Scanner, Dry Block Calibrator, 6½ Digit Multimeter and Multifunction calibrator by Comparison method
BOD incubator (0 - 100°C) 0 - 100 °C Using SSPRT with Precision Temperature Scanner by Comparison method
Temperature transducers (-80 to 1200°C) -80 °C - 1200 °C Using SSPRT with Super Precision Temperature Scanner, Dry Block Calibrator, 6½ Digit Multimeter and Multifunction calibrator by Comparison method
Temperature calibrator (-80 to 1500°C) -80 °C - 1200 °C Using SSPRT with Precision Temperature Scanner by Comparison method
Calibration of Ovens calibration (Amb. to 400°C) -80 °C - 1200 °C Using SSPRT with Precision Temperature Scanner by Comparison method
Thermocouple calibration -80 °C - 1200 °C Using SSPRT with Super Precision Temperature Scanner, Dry Block Calibrator, 6½ Digit Multimeter and Multifunction calibrator by Comparison method
Thermometer calibration -80 °C - 1200 °C Using SSPRT with Super Precision Temperature Scanner, Dry Block Calibrator, 6½ Digit Multimeter and Multifunction calibrator by Comparison method
Humidity chamber 5 - 50 °C / 20 - 95 % RH Using Temperature & Humidity Indicator with Sensor by Comparison method
Temperature data logger -80 °C - 1200 °C Using SSPRT with Super Precision Temperature Scanner, Dry Block Calibrator, 6½ Digit Multimeter and Multifunction calibrator by Comparison method
Temperature bath -80 °C - 1200 °C Using SSPRT with Precision Temperature Scanner by Comparison method
Temperature recorder -80 °C - 1200 °C Using SSPRT with Super Precision Temperature Scanner, Dry Block Calibrator, 6½ Digit Multimeter and Multifunction calibrator by Comparison method
Muffle furnace Amb. - 1200 °C Using SSPRT / S type Thermocoupe with Precision Temperature Scanner by Comparison method
RTD sensors calibration -80 °C - 660 °C Using SSPRT with Super Precision Temperature Scanner, Dry Block Calibrator, 6½ Digit Multimeter and Multifunction calibrator by Comparison method
Hygrometer 20 - 95 % RH Using Temperature & Humidity Indicator with Sensor and Temperature & Humidity Calibrator by Comparison method
Temperature transmitter / Transducer -80 °C - 1200 °C Using SSPRT with Super Precision Temperature Scanner, Dry Block Calibrator, 6½ Digit Multimeter and Multifunction calibrator by Comparison method
Humidity data logger / Data loggers / -25 - 50 °C / 20 - 95 % RH Using Temperature & Humidity Indicator with Sensor and Temperature & Humidity Calibrator by Comparison method
Deep freezer -80 °C - 25 °C Using SSPRT with Precision Temperature Scanner by Comparison method
Autoclave Mapping 121 °C Using RTD Sensors (Minimum 9) with Super Precision Temperature Scanner by Comparison method
Humidity Mapping 20 - 95 % RH Using Temperature & Humidity Data Loggers (Minimum 9) by Comparison method
Temperature Mapping -80 °C - 1200 °C Using RTD Sensors / Data loggers / THermocouples (Minimum 9) with Super Precision Temperature Scanner by Comparison method
Infrared thermometer / Non-contact Type Infrared Thermometer 50- 1200 °C Using High Stability Black Body Furnace & Non-contact on- line Pyrometer / Infrared Thermometer by Comparison method
Pyrometer / Thermal Imaging Camera 50- 1200 °C Using High Stability Black Body Furnace & Non-contact on- line Pyrometer / Infrared Thermometer by Comparison method
Black Body Furnace 50- 1200 °C Using Non-contact on-line Pyrometer / Infrared Thermometer by Comparison method

Thermal Calibration is widely used for instruments that measure:

  • Temperature (Contact & Non-Contact)
  • Humidity
  • Temperature Distribution (Mapping)
  • Surface Temperature
  • Infrared Radiation